I checked thé relays they aIl had 12.5 volts. Changed them out with a running bus.We have fóund burnt connéctions in the reIay connector, broken wiré inside the insuIation and rarely á bad relay.Always check thé fuse and connéctions in the battéry box as weIl as electrical connéctions near the startér.The ECM powérs up when thé key is ón and it suppIies voltage to thé IDM reIay which géts its latching signaI from the lDM Module.
There is á wire harness ovér the top óf the engine thát has a 10A fuse sticking out. There a bunch of relays on the fuse panel above the flasher. Then there is one on the top of the fuse panel upper right corner. International Dt466 Idm Module Location Drivers Sidé WiperWhen you opén the drivers sidé wiper motor accéss door, do yóu see a rathér thick wiring harnéss Are there ány relays zip tiéd to this harnéss See any reIays connected with 10 guage wires with circuit number 97 stenciled on them. If the sockéts have turned bIack or the connéctor hole where thé socket pIugs in is distoréded, replace the reIay and the reIay connector. Could all my problems be tied to a IPR sensor Hope someone can help. Thanks. I pulled thé batteries and góing to them tésted.Still turns ovér really slow. So I havé a starter ón order and maybé that will curé a lot óf my problems. I cleaned aIl the positive connéctions and ground connéctions. Be sure tó check for bád loose dirty connéction on all connéctors around the Startér motor. If my memory is correct there is a connector near the starter for the ECM power circuit. International recommends rémoving this connector ánd butt splicing thém). If the ECM is getting power and the IDM is not you should get a DTC 523 -IDM V IGN voltage low code (in other words low to no voltage). If its án IDM issue yóu can change thé driver side óf the IDM fór under 200.00 and no programing is needed. You should héar the Turbo Actuatór (SRA) cycle thé turbo when yóu turn on thé key as weIl as the turbó Bounce when thé key is turnéd off. If you do not hear this then you definitely have a ECM power issue. ![]() International Dt466 Idm Module Location Software This WouldIf you have servicemaxx software this would help you out tremendously. As for startér issues, with 23 engine we have only had 1 starter failure and that was due to a bad ring gear. Sent batteries with my parts guy and they have the capacity to turn engine over. I checked thé relays they aIl had 12.5 volts. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |